http://WWW.RUBYDENTALINDIA.COM
http://WWW.RUBYDENTALINDIA.COM

Checking delivery availability...

background-sm
Search
3

Updates found with '10 pcs'

Page  1 1

Updates found with '10 pcs'

Fully Eletric Dental Chair• Electric Chair with Zero Programs. • Seamless seat upholstery and PU molded arm rest. • Operated by Both foot control & switching on instrument tray for all movements. • Removable ceramic bowel and auto water timer control with switches. • X-Ray film viewer with white light. • Halogen light Fully Imported Reflector with two intensity. • Three point control for air rotor, air motor control and 3-way syringe. • Dental stool having pneumatic height adjustment. • Wide base of chair to stable the whole chair unit firmly. • Shift able side unit can be attached on either side.B. TECHNICAL SPECIFICATIONS 1. Power supply – 230 V± 10%, 50 Hz, 4 Amp. 2. Power rating of Motor – DC 24V, Max. 3.6Ams/50 W 3. Water Pressure – 2 to 4 Bar 4. Air Pressure – 5.5 to 8.0 Bar 5. Displacement :Total Length of seat - 1930 mm Upper Back Rest width- 609 mm Upper back rest length- 560 mm Lower seat length - 1144 mm Lower seat width - 484 mm SPECIAL FEATURES 1. X-Ray viewer with powerful illumination. 2. Routable Glass Spittoon & cup filler with timer water system. 3. 3-way syringe with removable & auto clearable tips. 4. Air Router Control Box with Air Filter & Pressure Control System RUBY DENTAL Pvt Ltd 1085, (1st Floor)Bazar Pai walan Near Gate No.3 Opp Fire Station Jama Masjid Delhi – 110006 (INDIA) Ph : 0091-11 –4524-1085 , 2326-6400, 2328-5001 & 2327-8569 Fax : 0091-11- 2327-8569 Cell : 98-111-44220, 98-917-95555 Email : rubydentalpvtltd@yahoo.co.in www.rubydental.net www.rubydental.in
Send Enquiry
Read More
Implant Motor / Oral Surgery Machine / Physio-DispenserOur most advanced Dental Implants and Oral Surgery Complete Digital System. Break through design of a high-torque, low-speed, geared motor.Usage in IMPLANT SURGERY:The Motor has 20:1 Reduction. Hence can be used with normal 1:1 Contra-Angle Hand Piece.Fixed Torque Varies 50 NCM.Speed Varies from 50 rpm to 40, 000 rpm.Physiological Saline Irrigation with Flow Control.Usage in ENDO SURGERY:Unique geared motor separate from hand piece delivers high-torque at low-speed. Works with straight 1:1 hand piece at low speed for endo surgery.No need to invest in Costly Endo Motors. Even lower cost of ownership - No more need to replace expensive specialized implant and endo hand pieces due to their frequent failures.Usage in ORAL SURGERY:Hand piece inherently operates at a reduced speed since the maximum RPM of the motor is 1, 000RPM versus other typical motors that work at 40, 000RPM.With the reduced speed of the motor, it is possible for a dentist to perform Oral bone surgery with a straight hand piece.Bone surgery at low speed becomes extremely safe and patients will typically not get any swelling after surgery.The only system in the world to have Irrigation and Slow speed up to 20 RPM during Oral Surgery.An Innovative System:Design uses an innovative speed reduction motor instead of using a speed reduction contra angle hand piece.Works with any standard E-type and contra-angle hand piece.Physiological Saline Irrigation with Flow Control (No Flow to high Flow)Foot Switch is given to control the Motor, to control the flow of Saline, Forward and Backward movement for Motor, Program of Surgery Paddle.MOTOR Comes in two settings: Reduction in Motor of 20:1. In this case, we have to attach Normal 1:1 Hand Piece to the Motor.Normal 1:1 Motor (Like All other system Physio-Dispensers) Reduction in Hand piece 20:1. Ruby Dental Pvt.Ltd1085, (1st Floor) Bazar Pai Walan Near Gate No.3 Opp Fire Station Jama Masjid Delhi – 110006Ph : 0091-11-45241085 , 23266400 , 23285001 , 23278569 Cell : 9811144220 , 9891795555
Send Enquiry
Read More
Implant Motor / Oral Surgery Machine / Physio-DispenserOur most advanced Dental Implants and Oral Surgery Complete Digital System. Break through design of a high-torque, low-speed, geared motor.Usage in IMPLANT SURGERY:The Motor has 20:1 Reduction. Hence can be used with normal 1:1 Contra-Angle Hand Piece.The Torque Varies from 10 NCM to 50 NCM.Speed Varies from 50 rpm to 40, 000 rpm.Physiological Saline Irrigation with Flow Control.Usage in ENDO SURGERY:Unique geared motor separate from hand piece delivers high-torque at low-speed. Works with straight 1:1 hand piece at low speed for endo surgery.No need to invest in Costly Endo Motors. Even lower cost of ownership - No more need to replace expensive specialized implant and endo hand pieces due to their frequent failures.Usage in ORAL SURGERY:Hand piece inherently operates at a reduced speed since the maximum RPM of the motor is 1, 000RPM versus other typical motors that work at 40, 000RPM.With the reduced speed of the motor, it is possible for a dentist to perform Oral bone surgery with a straight hand piece.Bone surgery at low speed becomes extremely safe and patients will typically not get any swelling after surgery.The only system in the world to have Irrigation and Slow speed up to 20 RPM during Oral Surgery.An Innovative System:Design uses an innovative speed reduction motor instead of using a speed reduction contra angle hand piece.Works with any standard E-type and contra-angle hand piece.Physiological Saline Irrigation with Flow Control (No Flow to high Flow)Foot Switch is given to control the Motor, to control the flow of Saline, Forward and Backward movement for Motor, Program of Surgery Paddle.MOTOR Comes in two settings: Reduction in Motor of 20:1. In this case, we have to attach Normal 1:1 Hand Piece to the Motor.Normal 1:1 Motor (Like All other system Physio-Dispensers) Reduction in Hand piece 20:1.
Send Enquiry
Read More
Page 1 0.9